3-Port Residual Pressure Relief Valve Main Valve Position Detection Series VP700

Contact

Product information:
Switching method: N.C.
Operating method: Internal pilot, external pilot
Operating pressure range: 0.25 to 0.7 MPa
External pilot pressure: 0.25 to 0.7 MPa
Maximum operating frequency: 30 times/minute
Minimum operating frequency: 1 time/week
Operating and ambient temperature: -10°C to 50°C (no freezing)
Ambient humidity: 20 to 90%RH (non-condensing)
Manual operation: None
Pilot exhaust method: Individual exhaust pipe
Lubrication: Not required
Attachment orientation: Freedom
Shockproof / Anti-vibration: 150/30 m/s²
Enclosure: IP65
Operating environment: Indoor
B10D (to calculate MTTFd): 10,000,000 times