The AX8525 and AX8540 combined power supply and axis modules unite the function of an AX86xx power supply module with an AX81xx axis module in a single device. As a result, the AX-Bridge is not loaded by the axis current of the first axis and up to 50 A DC are available for additional axis modules. The power supply provides 80 A DC to the DC link and contains an internal brake resistor as well as a chopper for the connection of an external brake resistor. The integrated axis module with TwinSAFE safety functions is available with a rated current of 25 A or 40 A and can optionally be ordered with multi-feedback interface.
The TwinCAT 3 Drive Manager 2 serves as commissioning tool. Thanks to the structured design and the wide range of functions, commissioning of the axis is simple and intuitive.
The TwinCAT 3 Safety Editor TE9000 and the TwinSAFE Loader/User TE9200 must be used to implement safety projects.
| Technical data | AX8525-0100-0000 |
|---|---|
| Function | combined power supply and axis module with TwinSAFE Logic |
| Channels | 1 |
| Rated supply voltage | 3 x 200…480 V AC |
| DC link voltage | max. 848 V DC |
| DC link output current | 80 A DC |
| Rated output current (channel) | 25 A |
| Peak output current (channel) | 50 A |
| Feedback | OCT , EnDat 3 |
| System bus | EtherCAT |
| Drive profile | CiA402 according to IEC 61800-7-201 (CoE) |
| Realization STO | by local TwinSAFE Logic, via FSoE or hard-wired via safe inputs |
| Safe stop functions | Safe Torque Off (STO), Safe Stop 1 (SS1) |
| Safety standard | EN ISO 13849-1:2015 (Cat 4, PL e), EN 61508:2010 (SIL 3) and EN 62061:2005 + A1:2013/A2:2015 (SIL CL3) |
| Ambient temperature (operation) | 0…+40°C, up to +55°C with power reduction (see documentation) |
| Approvals/markings | CE, cULus, EAC |





Reviews