Product information:
Product code: GL-R06L
Detection capacity: Lens diameter ø45 mm
Total length: 240 mm
Number of beam shafts: 6
Detection height: 200 mm
Protection height: 285 mm
Beam axis distance/Lens diameter: 40 mm / ø5
Detection distance: 0.2 to 15 m
Effective aperture angle: Maximum ±2.5° (When operating distance is 3 m or more)
Light source: Infrared LED (870 nm)
Response time (ms): Optical synchronization (Channel 0) or Wire synchronization: ON→OFF 6.6, OFF→ON 48.7; Optical synchronization (Channel A or B): ON→OFF 6.9, OFF→ON 49.1
Detection mode: Turns on when there is no interruption in the detection area
Synchronization between transmitter and receiver: Optical synchronization or Wire synchronization (determined by wire)
Anti-light interference function: Prevents mutual interference in up to two GL-R systems.
Control output (OSSD Output): 2 transistor outputs, maximum load current 500 mA
Power supply: Power supply voltage 24 VDC ±20%, ripple (PP) of 10% or less, Class 2
Safety standards: Reverse current protection, short circuit protection for each output, surge protection for each output (various safety standards)
Environmental resistance: Water and dust resistant IP65/IP67, ambient temperature from -10 to +55 °C
Storage temperature: -25 to +60 °C
Relative humidity: 15 to 85 % RH (Non-condensing)
Relative storage humidity: 15 to 95 % RH
Body protection type safety optical shield, 6 optical axes KEYENCE GL-R06L
Contact
Product information:
Product code: GL-R06L
Detection capacity: Lens diameter ø45 mm
Total length: 240 mm
Number of beam shafts: 6
Detection height: 200 mm
Protection height: 285 mm
Beam axis distance/Lens diameter: 40 mm / ø5
Detection distance: 0.2 to 15 m
Effective aperture angle: Maximum ±2.5° (When operating distance is 3 m or more)
Light source: Infrared LED (870 nm)
Response time (ms): Optical synchronization (Channel 0) or Wire synchronization: ON→OFF 6.6, OFF→ON 48.7; Optical synchronization (Channel A or B): ON→OFF 6.9, OFF→ON 49.1
Detection mode: Turns on when there is no interruption in the detection area
Synchronization between transmitter and receiver: Optical synchronization or Wire synchronization (determined by wire)
Anti-light interference function: Prevents mutual interference in up to two GL-R systems.
Control output (OSSD Output): 2 transistor outputs, maximum load current 500 mA
Power supply: Power supply voltage 24 VDC ±20%, ripple (PP) of 10% or less, Class 2
Safety standards: Reverse current protection, short circuit protection for each output, surge protection for each output (various safety standards)
Environmental resistance: Water and dust resistant IP65/IP67, ambient temperature from -10 to +55 °C
Storage temperature: -25 to +60 °C
Relative humidity: 15 to 85 % RH (Non-condensing)
Relative storage humidity: 15 to 95 % RH