series 6
Physical principles of Ultrasound
Application Detects non-transparent labels
Detect transparent labels
Label width, min. 10mm
Label spacing, min. 2mm
Medium transparent and opaque
GSU 06/24-2 three-way acoustic sensor
Contact
Protection circuit Polarity reversal protection
short circuit protection
Performance data
Supply voltage UB 10 … 30 V, DC
Residual Ripple 0 … 15 %, From UB
Open circuit current 0 … 40 mA
input
Number of teaching inputs 1 Piece(s)
teach input
Type Teaching input
DC voltage type
Switching voltage high: ≥8V low: ≤ 2 V
Input resistance 10,000 Ω
Teaching input 1
Active transition state High
output
Number of digital conversion outputs 2 Pcs
output conversion
Type Digital conversion output
DC voltage type
Current conversion, max. 100mA
Switching voltage high: ≥(UB-2V) low: ≤ 2 V
Switch output 1
Transistor switching element, PNP
Switching principle Switching signal in label gap
Switch output 2
Transistor switching element, NPN
Switching principle Switching signal in label gap
temporal behavior
Response time 0.3 ms
Ready delay 100 ms
max. Conveyor speed during teaching 50 m/min
Connector
Number of connections 1 Piece(s)
Gate 1
Signal IN function
OUT signal
Supply voltage
Connection cable type
Cable length 2,000 mm
Number of conductors: 5 wires
Mechanical data
fork design
Mouth width 2.5 mm
Mouth depth 48 mm
Dimensions (Width x Height x Length) 16.5 mm x 40 mm x 78 mm
Metal shell material
Aluminum metal case
Net weight 150 g
Shell color Red
Lanyard type Thread mounted
Through-hole mounting
Operation and display
LED screen type
Number of LED lights 2 Pieces
Operating controls Teach button
Environmental residue
Ambient temperature, operating 5 … 50 °C
Ambient temperature, storage -40 … 70 °C
certification
Protection level IP 62
Protection class III
US UL certification
Applicable standard IEC 60947-5-2